HBW01
HBWo1 applies to tank scales, belt scales, batching weighing systems.
Describe
Main Dimensions
| Rated load(Kg) | D | M |
| 5,10,20,30,40,50,75,100,150,200,250 |
Φ8.2 |
M8 |
| 300,500 |
Φ10.2 |
M10 |
Circuit Diagram
Specification
| Rated load (Emax) | 5,10,20,25,30,40,50,75,100,150,200,250.300,500kg |
Insulation resistance |
≥5000M Ω |
| Sensitivity | 2.0±0.002%mV/V |
Operating Temp Range |
(-30~+70)℃ |
| Combined error | ±0.02%F.S;±0.03%F.S |
Safe load limit |
150%F.S |
| Creep/30min | ±0.02%F.S/30min |
Ultimate overload |
200%F.S |
| Zero balance | ±1%F.S |
Recommend excitation |
10~12V DC or AC |
| TCO | ±0.02% F.S/10°c |
Max excitation |
15V DC |
| TC SPAN | ±0.02%F.S/10℃ |
Protection Class |
IP68 |
| Input resistance | 400±10Ω |
Material |
Alloy steel Stainless steel |
| Output resistance | 352±2Ω | Cable | Length:3m Diameter: Φ6mm |